Residential · central heating and apartment substations

Boiler on the roof,a substation in every flat.

Heating and hot water from the rooftop boiler room to every flat; water tanks, booster set, fire pump and car park ventilation in the basement. Let's tour the hidden mechanical systems of a residential building floor by floor.

↓ Scroll down
Rooftop boiler room · cascade condensing boilers

Heat for the whole buildingfrom a single room.

Three condensing boilers run in cascade: at light load one boiler is enough, and the others start in turn as demand rises. With the boiler room on the roof the flue stays short; condensate is neutralised before it is drained.

Natural gas line · gas safety · flue

Gas linestraight to the roof.

Natural gas rises from the meter up the façade straight to the rooftop boiler room. If the gas detector senses a leak, the shut-off valve cuts the gas; low and high louvres ventilate the room.

Hydraulic separator · circulation pumps · expansion vessel

Boiler circuit and building circuitnever upset each other.

The hydraulic separator decouples the boiler circuit from the building circuit. Variable-speed circulation pumps push hot water into the risers; the expansion vessel absorbs the expansion of the heated water and keeps system pressure steady.

Shaft · flow and return risers · balancing

The same pressureon every floor.

Flow and return risers run down the shaft to every floor. A differential pressure control valve on each floor keeps the pressure to the substations constant; the top-floor flat gets the same comfort as the ground-floor flat and no pump energy is wasted.

Heat interface unit (apartment substation)

The substationreplaces the combi.

The heat interface unit in each flat distributes hot water from the riser into the home. There is no gas or combustion inside: a plate heat exchanger, control valve, heat meter and electronic controller. Heating and hot water come from one compact unit.

Flat substation · cover open

A small box,a complete heat centre.

With the cover open: a strainer that cleans the water from the riser, a differential pressure regulator that holds pressure steady, a motorised valve for heating, a mixing pump for underfloor heating, a plate heat exchanger for hot water and a heat meter that measures consumption. The service valves below isolate the flat from the riser for maintenance.

Underfloor heating · room thermostat

Heat risesfrom the floor.

The substation feeds the underfloor heating loops at low temperature. Heat spreads evenly from the floor; when the room reaches its set point the thermostat throttles the valve in the substation. Low water temperature also raises the efficiency of the condensing boilers.

Instantaneous hot water · plate heat exchanger

Open the tap,hot water is ready.

When a tap opens, the plate heat exchanger in the substation instantly heats mains water with hot water from the riser. No cylinder or hot-water return line is needed; because hot water is not stored, the legionella risk is lower too.

Heat meter · remote meter reading

Everyone paysfor what they use.

The heat meter in each substation measures the heat energy delivered to the flat. Meters are connected to a central system over M-Bus; readings are taken without entering the flat and heating costs are shared by consumption.

Scenario · a winter morning

Demand rises,boilers start in turn.

At night one boiler is enough. At shower time in the morning the substations call for hot water at once; the cascade control brings in the second and third boilers and stops them in turn as the load falls. The simulation restarts about every 30 seconds.

    Basement · water tank and booster set

    Enough pressureeven on the top floor.

    Mains water is stored in the basement tank. A variable-speed booster set delivers enough pressure to the upper floors; the membrane vessel prevents the pumps from cycling on and off. The same line feeds the domestic water heated in the substations.

    Fire water tank · pump set · sprinklers

    Fire water,ready at all times.

    A pump set fed from a separate fire water tank supplies the car park sprinklers and hose reels; the jockey pump keeps the line under constant pressure. When a sprinkler head opens and pressure drops, the main pump starts automatically and the alarm valve triggers the fire alarm.

    Car park ventilation · jet fans · CO detection

    Exhaust fumesnever build up.

    Fresh air comes in at the inlet; ceiling jet fans push it along the car park towards the exhaust room and exhaust fans discharge it outside. CO detectors step the fans up and down according to gas levels. The ramp, stair and lift core and EV charging points are on the same level.

    Car park fire · sprinklers · smoke extraction

    In a fire, smoke is pushedone way only.

    When a car catches fire, the sprinkler heads above it open with the heat and the alarm sounds. Jet fans and exhaust fans switch to high speed; smoke is pushed away from the fresh-air inlet, towards the exhaust shaft. Firefighters can then approach the fire safely from the fresh-air side.

    Installation and contracting

    Let's plan yourresidential project together.

    Let's review your project together before installation; we install the boiler room, heat interface units, underfloor heating, water and fire systems, then carry out balancing and commissioning and hand it over.

    The animation shows an example residential building; it is not to scale.
    Message us on WhatsApp