The hidden systemsof a hotel.
From the guest room to the pool, from the kitchen to the car park: the mechanical systems of a hotel. Scroll and explore floor by floor.
Each roomwith its own climate.
With 4-pipe fan coils, rooms can be heated and cooled at the same time; every guest chooses their own temperature. When the key card is removed, the room switches to economy mode and no energy is wasted in an empty room.
Clean air,recovered energy.
The fresh air unit on the roof supplies filtered fresh air to corridors and rooms and extracts from the bathrooms. A heat recovery wheel transfers the energy of the exhaust air to the fresh air and reduces the load.
Cooling that alsomakes hot water.
Chillers on the roof produce chilled water and boilers in the basement produce hot water; pump sets distribute them to the fan coils in the rooms. A heat-recovery chiller transfers the waste heat from cooling to the domestic hot water.
From the sun, from waste heat,from a heat pump.
Solar collectors, chiller waste heat and a heat pump heat the calorifiers together; the boiler only tops up what is missing. Calorifiers are kept above 60 °C and the circulation loop keeps the legionella risk under control.
Clear water,a mist-free hall.
Pool water passes through sand filters, and pH and chlorine are adjusted by automatic dosing. In the indoor pool hall, the dehumidification unit removes evaporated water; it prevents condensation and corrosion and uses the recovered heat to warm the hall and the pool water.
Steam, warmthand comfort.
The steam generator serves the hammam and steam room; the sauna runs on its own heater. Ventilation and condensation control in wet areas extend the life of the spa.
Greasy fumescaptured at the source.
The hood exhaust discharges greasy fumes from the cooking line through the roof. The suppression system in the hood discharges automatically when it detects a fire and shuts off the gas. Kitchen wastewater passes through a grease separator before going to the sewer.
Even pressureat every tap.
Mains water is collected in a tank, softened in the softening unit and distributed to all floors at constant pressure by the booster set. The tank and booster protect the hotel from supply interruptions and pressure fluctuations.
Water readyon every floor.
The fire water tank and pump set are in the basement. The riser feeds the sprinkler lines and hose cabinets protecting the lobby, corridors and rooms.
Exhaust gasdoes not build up.
CO sensors continuously measure the air in the car park. As the level rises, the jet fans and exhaust fan start in stages and stale air is discharged through the shaft. Because nothing runs unnecessarily, energy is saved.
Escape routesstay smoke-free.
In a fire, the escape stair is kept at positive pressure by a pressurisation fan and smoke cannot enter the stair. In the car park, jet fans and exhaust fans switch to smoke extraction mode.
The whole hotelon one screen.
Room status, pool and spa values, plant, kitchen and car park are monitored from a single automation screen. Choose a scenario and see how the screen and the hotel change.
Let's plan your hotel projecttogether.
Let's review your project together before installation; we install the mechanical systems, carry out testing, adjusting and commissioning, and hand them over.